Sunday, February 5th.

Technical Specifications

Weight
(Approx)
Length
(Approx)
Height
(Approx)
Width
(Approx)
Micro-Climate Chamber130kg255cm173cm89cm
Trolley and Net90kg185cm81cm100cm
Control Cabinet60kg88cm95cm43cm

Power consumption 9.5Kw. Total

Compressed Air Requirements

9 litres per second at 7kg/cm² (23 cu.ft per minute at 100 psi), input via 10mm bore (3/8" dia), quick release fittings. Spray density adjustable between 15 to 45 psi. Compressors are available as an optional extra as an alternative to built in hospital air supply.

Water Reservoir

20 litres. Gives approx. 30 minutes continuous spray at a density given by 45 psi compressed air supply.

Heater (warm air)

Tubular type. 6 per heater. 750W each. Rating 9Kw. Total 2 x 4.5 Kw.

Fan Motor (warm air)

Type produces 300 cu.ft. of air per minute. Rating 0.25Kw at 2800 r.p.m. 2 per B.C.U.

Warm Air

With room ambient 21°C; Machine will produce a proportional temperature rise of approx. 23°C above ambient. Volume 600 cubic feet per minute.